FERRELLGAS INC -- PROPANE -- 6830-01-386-1396
===================== Product Identification =====================
Product ID:PROPANE
MSDS Date:06/01/1993
FSC:6830
NIIN:01-386-1396
=== Responsible Party ===
Company Name:FERRELLGAS INC
Address:1 LIBERTY PLZ
City:LIBERTY
State:MO
ZIP:64068-2970
Country:US
Info Phone Num:816-792-1600
Emergency Phone Num:CHEMTREC 800-424-9300
Chemtrec Ind/Phone:(800)424-9300
CAGE:0CH06
=== Contractor Identification ===
Company Name:C F C RECLAIMATION AND RECYCLING SERVICE INC
Address:318 N TREADAWAY
Box:560
City:ABILENE
State:TX
ZIP:79604
Country:US
Phone:9150-675-5311 FAX: 915-675-5324
CAGE:0XXK5
Company Name:COLEMAN CO,INC
Address:3600 N HYDRAULIC ST
Box:2931
City:WICHITA
State:KS
ZIP:67201-2931
Country:US
Phone:316-832-2710
Contract Num:SP0450-99-M-A770
CAGE:80309
Company Name:ESPECIAL GAS INC
Address:517 N 4TH ST
Box:298
City:ABILENE
State:TX
ZIP:79601-6028
Country:US
Phone:800 588-1126 / 915-675-5311
Contract Num:SP0450-00-M-SC89
CAGE:1L0Z6
Company Name:ESPECIAL GAS INC
Address:517 N 4TH ST
Box:298
City:ABILENE
State:TX
ZIP:79601-6028
Country:US
Phone:800 588-1126 / 915-675-5311
Contract Num:SP0450-00-M-SD81
CAGE:1L0Z6
Company Name:FERRELLGAS
Address:1 LIBERTY PLAZA
Box:City:LIBERTY
State:MO
ZIP:64068-2970
Country:US
Phone:816-792-1600; 816-792-6916
CAGE:0CH06
Company Name:INTERDYNE CORP.
Box:UNKNOW
CAGE:34310
Company Name:KAMPI COMPONENTS CO., INC.
Address:210 RT 13
Box:721
City:BRISTOL
State:PA
ZIP:19007-3517
Country:US
Phone:215-736-2000
CAGE:7Z016
============= Composition/Information on Ingredients =============
Ingred Name:PROPANE
CAS:74-98-6
RTECS #:TX2275000
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1000 PPM
ACGIH TLV:ASPHYXIANT; 9495
===================== Hazards Identification =====================
LD50 LC50 Mixture:PRODUCT'S LD50 (ORAL RAT) WAS NOT STATED
Health Hazards Acute and Chronic:CLASSIFIED AS A SIMPLE ASPHYXIANT.
MINIMUM OXYGEN CONTENT SHOULD BE 19.5% BY VOLUME UNDER NORMAL
ATMOSPHERIC CONDITIONS. CENTRAL NERVOUS SYSTEM DEPRESSANT. MAY
CAUSE ANEMIA AND IRREGULAR HEART RHYTHM.
Explanation of Carcinogenicity:MFR GAVE THE ABOVE LISTINGS (N/A) ON THE
MSDS BUT NO OTHER COMMENTS WERE RECORDED.
Effects of Overexposure:HIGH CONCENTRATION CAN LEAD TO SYMPTOMS RANGING
FROM DIZZINESS TO ANESTHESIA AND RESPIRATORY ARREST, IF INHALED.
EYES CAN BE MODERATELY IRRITATED.
Medical Cond Aggravated by Exposure:CAUTION IS RECOMMENDED FOR
PERSONNEL WITH PRE-EXISTING CENTRAL NERVOUS SYSTEM OR CHRONIC
RESPIRATORY DISEASES.
======================= First Aid Measures =======================
First Aid:REMOVE TO FRESH AIR. IF NOT BREATHING, ADMINISTER AIR, OXYGEN
OR CPR. SKIN: KEEP AFFECTED AREA WARM AND SUBMERGE IN LUKEWARM
WATER. FLUSH EYES IMMEDIATELY WITH WATER.
===================== Fire Fighting Measures =====================
Flash Point:=-104.4C, -156.F
Autoignition Temp:=504.4C, 940.F
Lower Limits:2.15
Upper Limits:9.60
Extinguishing Media:DRY CHEMICAL CLASS A-B-C, CARBON DIOXIDE, WATER
SPRAY OR HALON
Fire Fighting Procedures:STOP FLOW OF GAS. USE WATER TO COOL CONTAINERS
& WATER SPRAY TO DISPERSE UNIGNITED GAS OR VAPOR. USE SCBA IN
CONFINED SPACES. USE SELF-CONTAINED BREATHING APPARATUS IN CONFINED
SPACES. EVACUATE AREA U NTIL GAS DISSIPATES.
Unusual Fire/Explosion Hazard:FLAMMABLE LIQUID & GAS UNDER PRESSURE.
MAY FORM EXPLOSIVE MIXTURE W/AIR. FIRE EXPOSED CONTAINERS MAY
RUPTURE EXPLOSIVELY.
================== Accidental Release Measures ==================
Spill Release Procedures:KEEP PUBLIC AWAY. SHUT OFF GAS SUPPLY.
ELIMINATE SOURCES OF IGNITION. VENTILATE AREA. DISPERSE W/WATER
SPRAY. CONTACT BETWEEN SKIN & THESE GASES CAN CAUSE FREEZING OF
TISSUE.
Neutralizing Agent:MFR GAVE NO INFORMATION OF MSDS.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP CONTAINERS AWAY FROM HEAT SOURCES
& STORE CONTAINERS IN UPRIGHT POSITION. CONTAINERS SHOULD NOT BE
DROPPED. DO NOT EXCEED 130F(54.4C).
Other Precautions:CLOSE CONTAINER SERVICE VALVE WHEN NOT IN USE & WHEN
EMPTY. INSTALL PROTECTIVE CAP WHEN NOT CONNECTED FOR USE.
CONTAINERS, EVEN THOSE THAT HAVE BEEN EMPTIED, CAN CONTAIN
EXPLOSIVE VAPORS. DO NOT CUT, WELD, OR GRIND ON OR NEAR
CONTAINERS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE NIOSH OR MSHA APPROVED EQUIPMENT WHEN
AIRBORNE EXPOSURE LIMITS ARE EXCEEDED.
Ventilation:PROVIDE ADEQUATE VENTILATION TO MEET TLV. MECHANICAL
VENTILATORS MUST MEET N.E.C. REQUIREMENTS, BEING EXPLOSION PROOF.
Protective Gloves:IMPERVIOUS PLASTIC OR NEOPRENE COATED
Eye Protection:CHEMICAL-TYPE GOGGLES & FACE SHIELD
Work Hygienic Practices:AVOID BREATHING GAS SECURE & EVACUATE AREA IF
GAS IS SMELLED.
Supplemental Safety and Health
NONE
================== Physical/Chemical Properties ==================
HCC:G2
NRC/State Lic Num:NONE
Boiling Pt:=-42.2C, -44.F
Vapor Pres:208 PSIG
Vapor Density:1.52
Spec Gravity:0.51
Evaporation Rate & Reference:<1 N-BUAC=1
Solubility in Water:SLIGHTLY
Appearance and Odor:CLEAR, UNPLEASANT ODOR SIMILAR TO GARLIC (ODORIZED
BY ETHYL MERCAPTAN)
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS
Stability Condition to Avoid:HEAT, SPARKS, FLAME & BUILT-UP STATIC
ELECTRICITY. PREVENT VAPOR ACCUMULATION.
Hazardous Decomposition Products:CARBON MONOXIDE
Conditions to Avoid Polymerization:WILL NOT OCCUR.
==================== Disposal Considerations ====================
Waste Disposal Methods:CONTROLLED BURNING IN COMPLIANCE W/APPLICIABLE
CODES & LAWS. CONTACT SUPPLIER.
=================== MSDS Transport Information ===================
Transport Information:PER MSDS PSN IS LIQUIFIED PETROLEUM GAS,2.1,
UN1075
===================== Regulatory Information =====================
SARA Title III Information:40 CFR 302 (CERCLA SECTION 102): NO RQ FOR
PRODUCT OR ANY CONSTITUENT GREATER THAN 1% OR 0.1% (CARCINOGEN).
40 CFR 355 (SARA SECTIONS 301-304): NO TPQ FOR PRODUCT OR ANY
CONSTITUENT GREATER THAN 1% O R 0.1% (CARCINOGEN). 40 CFR 372
(SARA SECTION 313): NO TOXIC CHEMICAL IS PRESENT GREATER THAN 1% OR
0.1% (CARCINOGEN).
Federal Regulatory Information:NOT SUBJECT TO RCRA.
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.